null

The cookie settings on this website are set to 'allow all cookies' to give you the very best experience. Please click Accept Cookies to continue to use the site.

Underfloor Heating Biocide - DB 5100

(No reviews yet) Write a Review

SKU:
DB5100
Shipping:
Calculated at Checkout
Dilution Rate:
1 Litre per 100 Litre System
£23.99 (Inc. VAT)
£19.99 (Ex. VAT)
CHEMIPHASE | DB HEATING TREATMENT RANGE
DB 5100 – Underfloor Heating Water Treatment

DB 5100 is a specialist chemical formulation developed for water treatment in compatible underfloor heating systems. Containing isothiazolinone-based ingredients, dispersants and stabilisers, it is intended for professional assessment and dosing within suitable closed-loop heating installations.

Underfloor Heating

Developed for specialist treatment of compatible underfloor heating circuits.

Specialist Formulation

Contains isothiazolinone-based ingredients, dispersants and stabilisers.

Measured Dosing

Published dosing guidance of 1 litre per 100 litres of system water.

Professional Underfloor Heating Treatment

DB 5100 is designed for use within a planned heating system water treatment programme, subject to confirmation of the product's regulatory status and compatibility.

  • Specialist formulation for underfloor heating applications.
  • Concentrated product for measured system dosing.
  • Suitable for professional assessment in compatible closed-loop circuits.
  • Can form part of a planned system maintenance programme.
  • Available in 1L, 5L and 25L containers.
Intended Applications

For professional evaluation and use in compatible systems including:

  • Domestic wet underfloor heating circuits.
  • Compatible closed-loop heating installations.
  • Suitable underfloor heating manifolds and pipework systems.
  • Light commercial underfloor heating circuits.

Compatibility: Confirm suitability with the heating system manufacturer before use, including compatibility with pipework, seals, pumps, manifolds, inhibitors and glycol-based antifreeze.

System Dosing Guidance

The existing Chemiphase product information states a dosing rate of 1 litre per 100 litres of system water.

System Water VolumeCalculated DB 5100 Quantity
50 litres 500 ml
100 litres 1 litre
200 litres 2 litres
500 litres 5 litres

Important: These quantities are calculated from the existing published ratio. Confirm the appropriate concentration, technical instructions and regulatory suitability before dosing.

Professional Application Guidance
  1. Read the current product label and Safety Data Sheet.
  2. Confirm the product's regulatory suitability for the intended treatment.
  3. Check the heating system manufacturer's chemical compatibility requirements.
  4. Assess the condition of the system and any existing treatment chemicals.
  5. Determine the total system water volume and confirm the correct dose.
  6. Introduce through a suitable system dosing point, following the equipment manufacturer's instructions.
  7. Circulate thoroughly and check normal system operation.
  8. Monitor water quality and treatment condition during routine maintenance.

Do not mix with other water treatment chemicals without verified compatibility. Professional dosing is recommended.

Technical Product Information
Product DB 5100
SKU DB5100
Product Type Specialist underfloor heating water treatment
Stated Ingredients Isothiazolinones, dispersants and stabilisers
Published Dosing Rate 1 litre per 100 litres of system water
Application Compatible underfloor heating circuits
Pack Sizes 1 litre, 5 litres and 25 litres
Important Safety & Regulatory Information

DB 5100 is described as containing isothiazolinone-based ingredients. Read the current product label and Safety Data Sheet to establish the applicable hazard classification and protective measures.

Wear appropriate protective gloves and eye protection. Avoid skin and eye contact, and prevent uncontrolled release into drains or watercourses.

Biocidal use and antimicrobial performance claims are subject to applicable GB Biocidal Products Regulation requirements. Confirm the active substances, product type and regulatory status before use or supply for biocidal purposes.

Store in the original, tightly closed container in a cool, dry place. Keep away from children and animals. Dispose of unused product and packaging responsibly.

Safety Data Sheet & Technical Documentation

For the current DB 5100 Safety Data Sheet, technical specification, system compatibility guidance or regulatory information, please contact Chemiphase.

Request DB 5100 SDS (PDF)
Part of the Chemiphase DB Heating Treatment Range

DB 5100 is positioned for specialist underfloor heating applications. Chemiphase also supplies DB 5000 Corrosion Inhibitor, DB 5300 Inhibited Antifreeze and DB 5400 Heat Pump Water Treatment. Select products according to system requirements and verified chemical compatibility.

Need Underfloor Heating Treatment Advice?

Contact Chemiphase for DB 5100 technical information, commercial quantities and specialist heating system treatment enquiries.

Contact Chemiphase
All products manufactured by Chemiphase are developed under strict ISO 9001 conditions. Chemiphase work with industry worldwide delivering practical, cost effective solutions to resolve complex problems. If you require technical assistance, or information about our products, please contact our dedicated technical support team on: +44 (0) 1704 894808 or complete our Technical Support form.