Noise Reducer – Boiler & Central Heating System Noise Solution DB 5500

Noise Reducer – Boiler & Central Heating System Noise Solution DB 5500

(No reviews yet) Write a Review

SKU:
DB 5500
Shipping:
Calculated at Checkout
Dilution Rate:
1 Litre per 100 Litre System
£17.99 (Inc. VAT)
£14.99 (Ex. VAT)
CHEMIPHASE | DB CENTRAL HEATING TREATMENT RANGE
DB 5500 – Central Heating & Boiler Noise Reducer

DB 5500 is a specialist central heating water treatment formulated to help reduce certain unwanted operating noises in compatible domestic boiler and radiator systems. Developed for use in suitable closed-loop heating circuits, it provides a convenient chemical treatment option where system noise has been assessed and a noise-reducing additive is appropriate.

Noise Reduction

Formulated to help reduce certain heating system operating noises.

Boiler & Radiator Circuits

For compatible domestic central heating installations.

Simple System Dosing

Published guidance of 1 litre per 100 litres of system water.

Why Choose DB 5500?
  • Specialist formulation for heating system noise treatment.
  • Designed for compatible boiler and radiator water circuits.
  • Convenient concentrated liquid for measured dosing.
  • Suitable for consideration as part of professional heating system maintenance.
  • Available in 1L, 5L and 25L containers.
Suitable Applications

DB 5500 is intended for use in compatible heating installations, including:

  • Domestic central heating boiler circuits.
  • Radiator and associated pipework systems.
  • Suitable sealed central heating installations.
  • Heating systems where a qualified engineer has identified an appropriate chemical noise treatment.

Important: Boiler kettling, trapped air, pump faults, water hammer, limescale and sludge can produce similar noises but require different corrective actions. Diagnose the cause before treatment. DB 5500 does not replace mechanical repairs, system bleeding or cleaning.

System Dosing Guidance

The existing Chemiphase product information specifies 1 litre of DB 5500 per 100 litres of system water.

System Water VolumeCalculated DB 5500 Dose
50 litres 500 ml
100 litres 1 litre
200 litres 2 litres
500 litres 5 litres

These are calculated examples based on the published ratio. Confirm the correct dose and compatibility against the current technical instructions before application.

Directions for Use
  1. Read the current product label and Safety Data Sheet.
  2. Identify the source of the noise and confirm that chemical treatment is appropriate.
  3. Check compatibility with the boiler, heating system materials and existing water treatments.
  4. Determine the system water volume and calculate the required dose.
  5. Introduce DB 5500 through a suitable approved dosing point following the heating equipment manufacturer's instructions.
  6. Circulate the heating water to distribute the treatment. The existing product guidance specifies approximately 1–2 hours.
  7. Check system operation and assess whether the original noise has changed.
  8. Investigate persistent noise rather than automatically repeating the dose.

Important: Do not mix DB 5500 with other heating chemicals, including corrosion inhibitors or antifreeze, without verified compatibility. Seek professional advice for persistent or unusual boiler noises.

Technical Product Information
Product DB 5500 Noise Reducer
SKU DB 5500
Product Type Central heating noise treatment additive
Stated Composition Surfactants, anti-vibration agents and stabilisers
Published Dosage 1 litre per 100 litres of system water
Published Circulation Time 1–2 hours
Application Compatible central heating circuits
Pack Sizes 1 litre, 5 litres and 25 litres
Important Safety Information

The existing product listing states H315 – Causes skin irritation and H319 – Causes serious eye irritation. Verify the complete classification against the current formulation and Safety Data Sheet.

Wear suitable protective gloves and eye protection. Avoid contact with skin and eyes. Do not ingest or mix with incompatible chemicals.

Not intended for potable drinking water systems. Prevent uncontrolled release into drains and watercourses.

Store in the original tightly closed container in a cool, dry, secure location. Keep out of reach of children and dispose of waste according to applicable regulations.

Safety Data Sheet & Technical Documentation

For the latest DB 5500 Safety Data Sheet, technical specification, system compatibility information or treatment guidance, please contact Chemiphase.

Request DB 5500 SDS (PDF)
Part of the Chemiphase DB Heating Treatment Range

DB 5500 is positioned for heating system noise treatment. Where noise is caused by sludge, DB 5200 Fast Acting Cleaner or DB 5600 System Restorer may be more appropriate. DB 5700 is designed for specialist limescale removal, while DB 5000 provides corrosion and scale inhibition in compatible systems.

Need Advice on a Noisy Central Heating System?

Contact Chemiphase for DB 5500 technical information, product compatibility guidance and commercial quantities.

Contact Chemiphase
All products manufactured by Chemiphase are developed under strict ISO 9001 conditions. Chemiphase work with industry worldwide delivering practical, cost effective solutions to resolve complex problems. If you require technical assistance, or information about our products, please contact our dedicated technical support team on: +44 (0) 1704 894808 or complete our Technical Support form.