DB 5100 is a specialist chemical formulation developed for water treatment in compatible underfloor heating systems. Containing isothiazolinone-based ingredients, dispersants and stabilisers, it is intended for professional assessment and dosing within suitable closed-loop heating installations.
Developed for specialist treatment of compatible underfloor heating circuits.
Contains isothiazolinone-based ingredients, dispersants and stabilisers.
Published dosing guidance of 1 litre per 100 litres of system water.
DB 5100 is designed for use within a planned heating system water treatment programme, subject to confirmation of the product's regulatory status and compatibility.
- Specialist formulation for underfloor heating applications.
- Concentrated product for measured system dosing.
- Suitable for professional assessment in compatible closed-loop circuits.
- Can form part of a planned system maintenance programme.
- Available in 1L, 5L and 25L containers.
For professional evaluation and use in compatible systems including:
- Domestic wet underfloor heating circuits.
- Compatible closed-loop heating installations.
- Suitable underfloor heating manifolds and pipework systems.
- Light commercial underfloor heating circuits.
Compatibility: Confirm suitability with the heating system manufacturer before use, including compatibility with pipework, seals, pumps, manifolds, inhibitors and glycol-based antifreeze.
The existing Chemiphase product information states a dosing rate of 1 litre per 100 litres of system water.
| System Water Volume | Calculated DB 5100 Quantity |
|---|---|
| 50 litres | 500 ml |
| 100 litres | 1 litre |
| 200 litres | 2 litres |
| 500 litres | 5 litres |
Important: These quantities are calculated from the existing published ratio. Confirm the appropriate concentration, technical instructions and regulatory suitability before dosing.
- Read the current product label and Safety Data Sheet.
- Confirm the product's regulatory suitability for the intended treatment.
- Check the heating system manufacturer's chemical compatibility requirements.
- Assess the condition of the system and any existing treatment chemicals.
- Determine the total system water volume and confirm the correct dose.
- Introduce through a suitable system dosing point, following the equipment manufacturer's instructions.
- Circulate thoroughly and check normal system operation.
- Monitor water quality and treatment condition during routine maintenance.
Do not mix with other water treatment chemicals without verified compatibility. Professional dosing is recommended.
| Product | DB 5100 |
| SKU | DB5100 |
| Product Type | Specialist underfloor heating water treatment |
| Stated Ingredients | Isothiazolinones, dispersants and stabilisers |
| Published Dosing Rate | 1 litre per 100 litres of system water |
| Application | Compatible underfloor heating circuits |
| Pack Sizes | 1 litre, 5 litres and 25 litres |
DB 5100 is described as containing isothiazolinone-based ingredients. Read the current product label and Safety Data Sheet to establish the applicable hazard classification and protective measures.
Wear appropriate protective gloves and eye protection. Avoid skin and eye contact, and prevent uncontrolled release into drains or watercourses.
Biocidal use and antimicrobial performance claims are subject to applicable GB Biocidal Products Regulation requirements. Confirm the active substances, product type and regulatory status before use or supply for biocidal purposes.
Store in the original, tightly closed container in a cool, dry place. Keep away from children and animals. Dispose of unused product and packaging responsibly.
For the current DB 5100 Safety Data Sheet, technical specification, system compatibility guidance or regulatory information, please contact Chemiphase.
Request DB 5100 SDS (PDF)DB 5100 is positioned for specialist underfloor heating applications. Chemiphase also supplies DB 5000 Corrosion Inhibitor, DB 5300 Inhibited Antifreeze and DB 5400 Heat Pump Water Treatment. Select products according to system requirements and verified chemical compatibility.
Contact Chemiphase for DB 5100 technical information, commercial quantities and specialist heating system treatment enquiries.
Contact Chemiphase