CHEMIPHASE | DB CENTRAL HEATING TREATMENT RANGE
DB 5600 – Central Heating System Restorer

DB 5600 is a concentrated heating system cleaner developed for older central heating installations affected by accumulated sludge, rust and internal deposits. Its longer-circulation treatment is designed to help loosen contamination within compatible radiators, boilers and pipework before thorough flushing and inhibitor treatment.

Sludge & Rust Deposits

Helps loosen accumulated deposits in compatible heating circuits.

Older Heating Systems

Designed for established systems requiring extended cleaning.

Extended Circulation

Published treatment period of 1–7 days, subject to compatibility.

Why Choose DB 5600?
  • Developed for older heating systems with accumulated contamination.
  • Helps loosen sludge, rust and corrosion-related deposits.
  • May improve circulation where deposits are causing restrictions.
  • Longer treatment period than a typical fast-acting cleaner.
  • Prepares compatible systems for flushing and corrosion inhibitor treatment.
  • Available in 1L, 5L and 25L pack sizes.
Suitable Applications

DB 5600 is intended for professional cleaning of compatible heating installations, including:

  • Older domestic central heating systems.
  • Radiator circuits affected by accumulated sludge.
  • Heating pipework containing corrosion-related deposits.
  • Suitable sealed and open-vented heating circuits.
  • Systems requiring cleaning before fresh inhibitor treatment.

Compatibility: Check the boiler manufacturer's instructions, particularly for aluminium heat exchangers, seals, pumps and systems containing glycol or existing chemical treatments. Older systems should also be assessed for leaks and weakened components before cleaning.

Recommended Dosage

The existing Chemiphase product guidance specifies 1 litre of DB 5600 per 100 litres of system water.

System Water VolumeCalculated DB 5600 Dose
50 litres 500 ml
100 litres 1 litre
200 litres 2 litres
500 litres 5 litres

These quantities are calculated from the existing published ratio. Confirm the appropriate concentration and system compatibility against the current technical instructions before use.

Professional Directions for Use
  1. Read the current product label and Safety Data Sheet.
  2. Assess the heating system for leaks, corrosion damage and chemical compatibility.
  3. Determine the system water volume and calculate the required dose.
  4. Introduce DB 5600 through a suitable approved dosing point, following the heating equipment manufacturer's instructions.
  5. Circulate the cleaner under approved operating conditions. The existing product guidance specifies 1–7 days depending on contamination levels.
  6. Monitor the system during treatment and do not exceed the approved contact time.
  7. Drain and flush thoroughly to remove loosened deposits and cleaning residues.
  8. Refill with clean water and add a compatible corrosion inhibitor such as DB 5000, following its separate instructions.
  9. Check system pressure, circulation and operation after treatment.

Important: Do not mix with other cleaning chemicals or inhibitors unless compatibility is confirmed. Cleaning can expose existing leaks or defects in older heating systems. Mechanical repairs may still be necessary.

Technical Product Information
Product DB 5600 System Restorer
SKU DB 5600
Product Type Extended-circulation heating system cleaner
Stated Composition Dispersants, corrosion cleaners and descaling agents
Published Dosage 1 litre per 100 litres of system water
Published Circulation Time 1–7 days, subject to technical confirmation
Application Compatible older central heating systems
Pack Sizes 1 litre, 5 litres and 25 litres
Important Safety Information

The existing product listing identifies H315 – Causes skin irritation and H319 – Causes serious eye irritation. Confirm the complete hazard classification against the current formulation and Safety Data Sheet.

Wear suitable protective gloves and eye protection. Avoid contact with skin and eyes. Do not ingest or mix with incompatible chemicals.

Not suitable for potable drinking water systems. Prevent uncontrolled discharge of contaminated cleaning water and follow applicable waste disposal requirements.

Store upright in the original sealed container in a cool, dry location away from direct sunlight. Keep out of reach of children.

Safety Data Sheet & Technical Documentation

For the current DB 5600 Safety Data Sheet, system compatibility information and professional cleaning guidance, please contact Chemiphase.

Request DB 5600 SDS (PDF)
Part of the Chemiphase DB Heating Treatment Range

DB 5600 is intended for longer-circulation cleaning of older heating systems. For faster routine cleaning, consider DB 5200 Fast Acting Cleaner. For specialist limescale removal, consider DB 5700 Descaler. After suitable cleaning and flushing, DB 5000 Corrosion Inhibitor helps protect compatible heating circuits.

Need Advice on Restoring an Older Heating System?

Contact Chemiphase for DB 5600, system cleaning advice, commercial quantities and technical support.

Contact Chemiphase
All products manufactured by Chemiphase are developed under strict ISO 9001 conditions. Chemiphase work with industry worldwide delivering practical, cost effective solutions to resolve complex problems. If you require technical assistance, or information about our products, please contact our dedicated technical support team on: +44 (0) 1704 894808 or complete our Technical Support form.