null

The cookie settings on this website are set to 'allow all cookies' to give you the very best experience. Please click Accept Cookies to continue to use the site.

System Cleaner Fast Acting DB 5200

System Cleaner Fast Acting DB 5200

(No reviews yet) Write a Review

SKU:
DB-5200
Shipping:
Calculated at Checkout
Dilution Rate:
1 Litre per 100 Litre System
£17.99 (Inc. VAT)
£14.99 (Ex. VAT)
CHEMIPHASE | DB CENTRAL HEATING TREATMENT RANGE
DB 5200 – Fast Acting Central Heating System Cleaner

DB 5200 is a concentrated central heating cleaner formulated to help remove sludge, rust deposits, scale and accumulated debris from compatible domestic heating systems. Designed for cleaning boiler, radiator and pipework circuits before flushing and adding a suitable corrosion inhibitor, it helps address circulation problems caused by internal deposits.

Sludge & Deposit Removal

Helps loosen accumulated sludge, rust deposits and debris.

Fast Acting Cleaner

Published initial circulation time of approximately 1–2 hours.

Pre-Inhibitor Treatment

Designed for cleaning before flushing and inhibitor dosing.

Why Choose DB 5200?
  • Helps remove black iron oxide sludge and accumulated heating system debris.
  • Assists with cleaning rust and suitable mineral deposits.
  • Can help improve water circulation where deposits are causing restrictions.
  • Suitable for cleaning compatible heating systems before inhibitor treatment.
  • Concentrated formula with simple volume-based dosing.
  • Available in 1L, 5L and 25L containers.
Suitable Heating Applications

DB 5200 is intended for cleaning compatible domestic heating installations, including:

  • Central heating boiler circuits.
  • Radiator and associated pipework systems.
  • Suitable sealed and open-vented heating circuits.
  • Heating systems affected by sludge and internal deposits.
  • Pre-flush cleaning before adding corrosion inhibitor.

Compatibility: Check the boiler manufacturer's requirements before use, particularly for aluminium heat exchangers, sensitive components, seals and systems containing glycol or other treatment chemicals.

Recommended Dosage

The existing Chemiphase product instructions specify 1 litre of DB 5200 per 100 litres of system water.

System water volumeCalculated DB 5200 dose
50 litres 500 ml
100 litres 1 litre
200 litres 2 litres
500 litres 5 litres

Calculate the required quantity from the actual system water volume. Confirm the dosing rate against the current technical instructions before treatment.

Directions for Use
  1. Read the current DB 5200 label and Safety Data Sheet.
  2. Confirm compatibility with the heating system and existing chemicals.
  3. Determine the total system water volume and calculate the required dose.
  4. Introduce DB 5200 through a suitable approved dosing point, following the heating system manufacturer's instructions.
  5. Circulate at normal operating temperature for approximately 1–2 hours, where permitted by the system and current product instructions.
  6. For heavily contaminated systems, the existing guidance allows circulation for up to 24 hours, subject to compatibility and technical confirmation.
  7. Drain and flush the system thoroughly to remove loosened deposits and cleaning residues.
  8. Refill with clean water and add a compatible corrosion inhibitor such as DB 5000, following its separate dosing instructions.
  9. Check system pressure, circulation and normal operation after treatment.

Important: Do not mix with other cleaning chemicals or inhibitors during treatment unless compatibility is confirmed. Severely blocked or damaged systems may require specialist mechanical cleaning or repair.

Technical Product Information
Product DB 5200 Fast Acting System Cleaner
SKU DB-5200
Product type Central heating system cleaner
Primary application Sludge, rust deposit and debris removal
Published dosage 1 litre per 100 litres of system water
Initial circulation time Approximately 1–2 hours
Extended circulation Up to 24 hours, subject to verification
Pack sizes 1 litre, 5 litres and 25 litres
Important Safety Information

Read the current DB 5200 label and Safety Data Sheet before use. Follow the specified hazard warnings and wear suitable protective gloves, eye protection and any other required personal protective equipment.

Avoid skin and eye contact. Do not ingest or mix with other chemicals. Prevent uncontrolled release of cleaning solution or contaminated heating water into drains and watercourses.

Store securely in the original container, away from children and incompatible substances. Dispose of spent cleaning solution and packaging in accordance with applicable waste requirements.

Safety Data Sheet & Technical Documents

For the current DB 5200 Safety Data Sheet, technical specification, system compatibility guidance or professional cleaning instructions, contact Chemiphase.

Request DB 5200 SDS (PDF)
Part of the Chemiphase DB Heating Treatment Range

Use DB 5200 for general heating system cleaning before flushing and inhibitor treatment. DB 5700 is intended for specialist mineral scale removal, while DB 5600 is positioned for older heating systems with accumulated deposits. After cleaning, DB 5000 Corrosion Inhibitor can help protect compatible systems against future corrosion and scale formation.

Need Central Heating Cleaning Advice?

Contact Chemiphase for DB 5200, heating system cleaning chemicals, commercial quantities and technical support.

Contact Chemiphase
All products manufactured by Chemiphase are developed under strict ISO 9001 conditions. Chemiphase work with industry worldwide delivering practical, cost effective solutions to resolve complex problems. If you require technical assistance, or information about our products, please contact our dedicated technical support team on: +44 (0) 1704 894808 or complete our Technical Support form.