CHEMIPHASE | INDUSTRIAL WATER TREATMENT
CP 9730 – Cooling Water Acid-Based Cleaning Agent
CP 9730 is a specialist industrial cooling water cleaning treatment formulated with a corrosion inhibitor. Designed for suitable cooling towers and recirculating water systems, it helps manage deposits and fouling as part of a professionally controlled cleaning and maintenance programme.
System Cleaning
Designed to help manage cooling water deposits and fouling.
Corrosion Inhibited
Includes corrosion-inhibiting technology for suitable systems.
Industrial Supply
Available in 25L and 205L drums.
Features & Applications
- Specialist cleaning treatment for industrial cooling water circuits.
- Published as an acid-based formulation incorporating a corrosion inhibitor.
- Intended for selected cooling towers and recirculating water systems.
- Can be considered for continuous treatment or one-off cleaning, subject to technical assessment.
- Formulated for a low treatment rate and stable performance.
- Suitable for industrial maintenance programmes where chemical compatibility has been established.
Directions for Use
CP 9730 should only be introduced following an assessment of the system, the deposits requiring treatment and the compatibility of all wetted materials.
- Inspect: Identify the type and extent of deposits, system condition and operating requirements.
- Confirm compatibility: Check the formulation against system metals, seals, pipework and existing treatment chemicals.
- Establish dosage: Obtain an appropriate treatment concentration and cleaning procedure for the application.
- Apply: Introduce through suitable chemical dosing equipment in accordance with the agreed procedure.
- Monitor: Check cleaning progress, system condition and water quality throughout treatment.
- Complete: Follow the specified flushing, neutralisation or disposal procedure where applicable.
Published dosage: The original product description references continuous dosing at 10–20 ppm and also mentions one-off cleaning. These are different applications; the appropriate dose, contact time and treatment method must be confirmed before use.
Technical Information & Pack Sizes
| Product |
CP 9730 Cooling Water Acid-Based Cleaning Agent |
| SKU |
CP9730 |
| Appearance |
Amber Liquid |
| Odour |
Sweet, Aromatic |
| Published Density at 20°C |
0.9 – Subject to Verification |
| Published Flash Point |
62–65°C – Subject to Verification |
| Product Description |
Acid-Based Cleaning Agent with Corrosion Inhibitor |
| Application |
Suitable Industrial Cooling Water Systems |
| Published Dosing Reference |
10–20 ppm for Continuous Treatment, Subject to Confirmation |
| Storage |
Follow Current SDS; Published Temperature Ranges Require Reconciliation |
| Published Shelf Life |
36 Months in Original Unopened Container, Subject to Verification |
| Selectable Pack Sizes |
25 Litre Drum and 205 Litre Drum |
Safety, Compatibility & Documentation
CP 9730 is marketed as an acid-based industrial cleaning product. Consult the current Safety Data Sheet for its verified chemical classification, flammability information, personal protective equipment, handling and storage requirements.
Do not assume compatibility with every cooling system material. Never mix concentrated cleaning chemicals with hypochlorite, oxidising biocides or other treatments unless an approved technical procedure specifically permits it.
Cooling tower cleaning should form part of a suitable risk assessment and microbiological control programme. For product-specific documentation and technical advice, contact Chemiphase.
Request SDS & Technical Information
Frequently Asked Questions
What is CP 9730 used for?
CP 9730 is marketed for cleaning suitable industrial cooling water systems and helping manage deposits and fouling.
Does CP 9730 contain a corrosion inhibitor?
Yes. The published description identifies a built-in corrosion inhibitor. System compatibility must still be confirmed.
Can CP 9730 be used for one-off cleaning?
The existing technical description identifies one-off cleaning as an application. The appropriate concentration, contact time and procedure must be established before treatment.
How much CP 9730 should I use?
The published continuous-treatment reference is 10–20 ppm, but the required dosage depends on the system and cleaning objective. Seek technical confirmation before dosing.
Need Industrial Cooling System Cleaning Advice?
Contact Chemiphase for CP 9730 product information, bulk supply and specialist cooling water treatment guidance.
Contact Chemiphase